• Model:EA1000VX
  • Product:X-ray Fluorescence Analyzer

 ♦  High-end model for RoHS application
 ♦  High Count Rate Detector (Vortex®)
 ♦  Hazardous Substance Measurement Software
        Ver.2

High speed measurement


Measurement time has been dramatically improved over standard instruments: one tenth for metal samples and one third for plastic samples compared with the conventional model SEA1000AII. This results in far greater overall throughput.

   Cd, Pb, Hg, Br, Cr in plastics Cd, Pb, Hg, Cr in high concentration BrSb plastics Cd, Pb, Hg, Br, Cr in brasses
EA1000VX Approximately 30 sec Within 120 sec Within 200 sec
SEA1000AII Approximately 100 sec Within 360 sec More than 2000 sec

 

 

High Count Rate Detector (Vortex®)


The EA1000VX is equipped with the high count rate Vortex detector.

 

 

Material ID Function


The EA1000VX rapidly identifies materials of different types of samples as soon as the measurement starts. Previously, an analytical recipe had to be selected first, but now there is no need to select an analytical recipe; the instrument can automatically identify a material.

 

 

Improved operability - Operation Panel


The user can monitor the measurement status via the progress bar on the Operation Panel as well as the sound indicators.

 

 

New Version of Hazardous Substance Measurement Software with a Variety of New Functions


Software manages the data (retrieval, browsing, analysis, editing, printing, and report preparation) measured by one or more instrument, allowing higher inspection efficiency and cost reduction.

 

 

Standard reference materials for various environmental regulations (optional)


A variety of standard reference samples developed and manufactured in-house are available; those include not only for the RoHS restricted elements (Cd, Pb, Hg, Br, and Cr), but also for other elements such as chlorine (Cl), antimony (Sb) and tin (Sn) and so forth.

Item Specification
Origin Japan
Elements Al13 to U92
Sample type Solid, Powder, Liquid
X-ray source X-ray tube (Rh target)
Voltage: 15 kV, 40 kV, 50 kV
Current: 1 mA (10 μA to 1,000 μA variable)
X-ray irradiation direction Bottom-Up method
Detector Vortex® (SDD) (Liquid nitrogen not required)
Analysis Area 1 mm, 3 mm, 5 mm (automatic switching)
Sample imaging Color CCD camera
Filters 5 mode automatic switching (including OFF)
Sample chamber 370(W)×320(D)×120(H) mm
Size 520(W)×600(D)×445(H) mm
Weight 60Kg
Software X-ray Station
  • Qualitative Analysis
  • Quantitative Analysis (Bulk FP, Bulk Calibration)
  • Routine Measure
Environmentally regulated substance measurement software Ver. 2
Power usage AC100~240V (50/60Hz) / 210VA

Classification Title Date